Semi-hermetic suction gas-cooled reciprocating compressor in compact design. The best possible serviceability is provided by means of a replaceable drive motor, among other things. The compressor stands out due to its outstanding running comfort and efficient operating perbance. The suction shut-off valve can be rotated by 90° in each instance. Dependable mechanism lubrication is guaranteed by means of an oil pump which is independent of rotating direction, as well as a large-volume oil sump. An electronic motor protection uses PTC sensors in series to monitor the winding temperature and, if desired, the discharge gas temperature.
Colour: blue (RAL 5000)
Technical data
HGX34e/315-4 S
Application
|
Refrigeration & AC
|
Compressor refrigeration capacity
|
21.50 kW
|
Power consumption
|
7.90 kW
|
Current draw (400 V)
|
13.30 A
|
Mass flow
|
0.202 kg/s
|
at following operating condition:
Refrigerant
|
R404A, R507
|
Reference temperature
|
Dew point
|
Evaporating temperature
|
5.0 °C
|
Condensing temperature
|
50.0 °C
|
Supply frequency
|
50 Hz
|
Voltage
|
400 V
|
Suction gas temperature
|
20 °C
|
Subcooling (outside cond.)
|
0 K
|
Number of cylinders / Bore / Stroke
|
4 / 50 mm / 40 mm
|
Displacement 50/60 Hz (1450/1740 1/min)
|
27,30 / 32,80 m3/h
|
Voltage 1)
|
220-240V Δ / 380-420V Y -3- 50Hz
|
|
265-290V Δ / 440-480V Y -3- 60Hz
|
Max. working current 2)
|
25.5 / 14.7 A
|
Max. power consumption 2)
|
8.9 kW
|
Starting current (rotor blocked) 2)
|
132.0 / 76.0 A
|
Motor protection
|
INT69 G
|
Protection terminal box
|
IP 66
|
Weight
|
96 kg
|
Frequency range 3)
|
25 - 70 Hz
|
Max. permissible overpressure (g) (LP/HP) 4)
|
19 / 28 bar
|
Connection suction line SV
|
28 mm - 1 1/8 "
|
Connection discharge line DV
|
22 mm - 7/8 "
|
Lubrication
|
Oil pump
|
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A
|
BOCKlub E55
|
Oil type R22
|
BOCKlub A46
|
Oil charge
|
1,3 Ltr.
|
Dimensions Length / Width / Height
|
535 / 282 / 318 mm
|
Sound power level LWA 5)
|
71 db(A) @ -35/+40 °C
|
|
67 db(A) @ -10/+45 °C
|
|
67 db(A) @ +5/+50 °C
|
Sound pressure level LpA 5)
|
58 db(A) @ -35/+40 °C
|
|
55 db(A) @ -10/+45 °C
|
|
54 db(A) @ +5/+50 °C
|
Scope of supply
Semi-hermetic four cylinder reciprocating compressor with drive motor
Single-section compressor housing with hermetically integrated electric motor
Winding protection with PTC resistor sensors and electronic trigger unit INT69 G
115-230 V AC, 50/60 Hz, IP00
Oil pump
Possibility for connection of oil pressure safety switch MP55
Possibility of connection of oil level controllers ESK, Traxoil, AC+R or CARLY 6)
Oil charge:
HG: BOCKlub A46
HGX: BOCKlub E55
Sight glass
Suction and discharge line valve
Inert gas charge
Accessories
(Digital) capacity regulator DCR14 230 V - 1 - 50/60 Hz, IP65
possible equippment see
Cylinder cover prepared for digital capacity regulator
Oil sump heater
110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
PTC heater self-regulating
Thermal protection thermostat per cylinder cover 7)
Oil pressure safety switch MP55 230 V - 1 - 50/60 Hz, IP20 8)
USB converter for INT69 G Diagnose 8)
INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)
DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 8)
Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 8)
Additional fan
230 V AC - 1 - 50 Hz, 97 W, IP44
230 V AC - 1 - 60 Hz, 128 W 8)
Step protection
Injection nozzle for liquid injection 8)
4 anti-vibration pads enclosed
Special voltage and/or frequency (on request)
Notes
1)
|
Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request
All data are based on voltage rms values
|
2)
|
- The stated value for the max. power consumption is valid for the adjusted power supply.
- Starting current (rotor blocked):
-
Part winding (PW) motors: Winding 1 / Winding 1+2
-
Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max. operating current / max. power consumption for designing motor contractors, feed lines, fuses and motor protection switches. Motor contractors: Consumption category AC3.
|
3)
|
The maximum permissible working current of the compressor (Imax) must not be exceeded. Take account of the guidelines for use of frequency inverter (see compressor assembly instruction or selection software).
|
4)
|
LP = Low pressure
HP = High pressure
|
5)
|
Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.
-
A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement bs of the ISO 3740 standard with accuracy class 2 or higher were used .
-
A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.
|
6)
|
Only with additional adapter possible
|
7)
|
Mounted
|
8)
|
Enclosure
|